Our labs are equipped with various instruments for material characterization and chemical analysis. Below is a summary of our equipment.

5.jpg
7890B GC System (Agilent Tech.)
  • Flame Ionization Detector (FID)
  • Thermal Conductivity Detector (TCD)
  • HP-5 and Stabilwax (Fused Silica) Columns 
  • Split/Splitless Injectors
  • GC Valve
11.jpg
Nicolet™ iS50 FTIR Spectrometer
  • Mercury Cadmium Telluride Detector (MCT)
  • Praying Mantis™Diffuse Reflection Accessory (Harrick Scientific)
  • Attenuated-Total Reflection (ATR)
  • High Vacuum Pump (Edward, 10^-5 Torr)
1.jpg
NMR.jpg
Bruker 500MHz NMR Spectroscopy
  • Bruker 500 MHz NMR
  • 5mm BBO Probe with z-Gradient
  • 5mm BBI Probe with z-Gradient
  • 5mm Bruker TXI (Inverse Triple Resonance ) Probe (1H, 13C and 15N) with xyz-Gradients
TGA.jpg
TGA Q500 TA Instruments
  • Quadrupole Mass Spectrometer
  • EGA Furnace (into Quartz)
  • Platinium and Alumina Sample Pans
  • Up to 1000°C
2.jpg
ASAP 2020 MICROMERITICS Porosimetry System 
  • HighVacTM (highvacuum,adds 10-mmHg transducer) 
  • Micropore (adds 1-mmHg transducer, requires HighVac) 
  • Pore Size Range: 3.5 to 5000 A 
  • Isothermal Jacket Cold Zone
3.jpg
RAMANRXN1 Analyzer from Kaiser Optical Systems, Inc.
  • TE-Cooled CCD Detector
  • 532 nm Wavelength (Green)
  • High Spatial Resolution up to Sub-micron Scale
  • No Sample Preparation Needed
1.png
Rigaku Benchtop Single Crystal X-ray Diffractometer
  • Rigaku XtaLAB mini II
  • 1.5418 Ångström Wavelength
  • Crystal Structure Determination
  • Powder
1.jpg
Series 5500 HP Reactors, Parr Instrument Company
  • Stand: Bench Top
  • Model 4848 Temperature Controller
  • Variable Speed Motor
  • High Pressure Compact Reactor Vessel (50 mL)
  • Standard Pressure MAWP Rating, psi (bar): 3000 (200)
1.jpg
Packed-Bed Flow Reactors
  • Mass Flow Controller 
  • Tube Furnace + Controller
  • Check/Stop Valve
  • Selective Catalytic Reduction (SCR) and Methane Oxidation
6.jpeg
Evolution™ 300 UV-Vis Spectrophotometer
  • Xenon Flash Lamp
  • Low Pressure Mercury Vapor Lamp
  • Wavelength Range: 190-1100 nm
  • Wavelength Accuracy: +/- 0.2 nm
  • Typical Lifetime: >5 years. Longer if Not Using Live Signal​
8.jpg
Thermo Scientific Heratherm Oven
  • Temperature Up to 250 °C
  • Temp Display: Vacuum Fluorescent
  • Power (VAC): 120 Power (Hz): 60 Power (amps): 12
  • Heratherm GP Mechanical Oven
  • Rotating Racks for Autoclaves
DLS.jpg
Wyatt Technology Dynamic Light Scattering (DLS)
  • Uses industry-standard 96, 384 or 1,536 microwell plates
  • Sample volume as low as 4 μL
  • User friendly experiment design in Dynamics
  • As sensitive as a cuvette-based DLS
  • First and only A2 and Mw in a plate
  • Film- or oil-based evaporation seal
  • Measure from 4º to 85ºC
  • Infrared wavelength not susceptible to fluorescence
  • 21 CFR Part 11 compliant software